Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland)
CC BY
Lưu vào:
Tác giả chính: | , , |
---|---|
Ngôn ngữ: | Vietnamese |
Nhà xuất bản: |
Springer
2023
|
Chủ đề: | |
Truy cập trực tuyến: | https://link.springer.com/article/10.1007/s10967-023-08882-9 https://dlib.phenikaa-uni.edu.vn/handle/PNK/8219 |
Từ khóa: |
Thêm từ khóa
Không có từ khóa, Hãy là người đầu tiên đánh dấu biểu ghi này!
|
id |
oai:localhost:PNK-8219 |
---|---|
record_format |
dspace |
spelling |
oai:localhost:PNK-82192023-04-21T08:10:46Z Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland) Lidia, Fijałkowska-Lichwa Tadeusz A., Przylibski Maciej, Norenberg SRDN-3a probe AlphaE detector CC BY The semi-conductor SRDN-3a probe, an AlphaE detector with a silicon diode in a diffusion chamber, an AlphaGUARD monitor with an ionization chamber and CR-39 track detectors had been tested simultaneously in long-term measurements conducted in the technical corridor of Dobromierz dam. The passive detectors were exposed twice: for 56 days, and 117 days, others in parallel, with a 1-h data recording interval. The data distribution was tested with the Shapiro–Wilk test and outliers in the critical region were identified using Shewhart control charts. The correctness was evaluated by a z-score test recommended by the IAEA. The characteristics of outliers for each detectors are determined by the location of the critical region (a two-sided region and a positive skew). 2023-04-21T08:10:46Z 2023-04-21T08:10:46Z 2023 https://link.springer.com/article/10.1007/s10967-023-08882-9 https://dlib.phenikaa-uni.edu.vn/handle/PNK/8219 vi application/pdf Springer |
institution |
Digital Phenikaa |
collection |
Digital Phenikaa |
language |
Vietnamese |
topic |
SRDN-3a probe AlphaE detector |
spellingShingle |
SRDN-3a probe AlphaE detector Lidia, Fijałkowska-Lichwa Tadeusz A., Przylibski Maciej, Norenberg Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland) |
description |
CC BY |
author |
Lidia, Fijałkowska-Lichwa Tadeusz A., Przylibski Maciej, Norenberg |
author_facet |
Lidia, Fijałkowska-Lichwa Tadeusz A., Przylibski Maciej, Norenberg |
author_sort |
Lidia, Fijałkowska-Lichwa |
title |
Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland) |
title_short |
Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland) |
title_full |
Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland) |
title_fullStr |
Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland) |
title_full_unstemmed |
Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland) |
title_sort |
intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in dobromierz (sw poland) |
publisher |
Springer |
publishDate |
2023 |
url |
https://link.springer.com/article/10.1007/s10967-023-08882-9 https://dlib.phenikaa-uni.edu.vn/handle/PNK/8219 |
_version_ |
1763815060366426112 |
score |
8.891145 |