Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland)

CC BY

Lưu vào:
Hiển thị chi tiết
Tác giả chính: Lidia, Fijałkowska-Lichwa, Tadeusz A., Przylibski, Maciej, Norenberg
Ngôn ngữ:Vietnamese
Nhà xuất bản: Springer 2023
Chủ đề:
Truy cập trực tuyến:https://link.springer.com/article/10.1007/s10967-023-08882-9
https://dlib.phenikaa-uni.edu.vn/handle/PNK/8219
Từ khóa: Thêm từ khóa
Không có từ khóa, Hãy là người đầu tiên đánh dấu biểu ghi này!
id oai:localhost:PNK-8219
record_format dspace
spelling oai:localhost:PNK-82192023-04-21T08:10:46Z Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland) Lidia, Fijałkowska-Lichwa Tadeusz A., Przylibski Maciej, Norenberg SRDN-3a probe AlphaE detector CC BY The semi-conductor SRDN-3a probe, an AlphaE detector with a silicon diode in a diffusion chamber, an AlphaGUARD monitor with an ionization chamber and CR-39 track detectors had been tested simultaneously in long-term measurements conducted in the technical corridor of Dobromierz dam. The passive detectors were exposed twice: for 56 days, and 117 days, others in parallel, with a 1-h data recording interval. The data distribution was tested with the Shapiro–Wilk test and outliers in the critical region were identified using Shewhart control charts. The correctness was evaluated by a z-score test recommended by the IAEA. The characteristics of outliers for each detectors are determined by the location of the critical region (a two-sided region and a positive skew). 2023-04-21T08:10:46Z 2023-04-21T08:10:46Z 2023 https://link.springer.com/article/10.1007/s10967-023-08882-9 https://dlib.phenikaa-uni.edu.vn/handle/PNK/8219 vi application/pdf Springer
institution Digital Phenikaa
collection Digital Phenikaa
language Vietnamese
topic SRDN-3a probe
AlphaE detector
spellingShingle SRDN-3a probe
AlphaE detector
Lidia, Fijałkowska-Lichwa
Tadeusz A., Przylibski
Maciej, Norenberg
Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland)
description CC BY
author Lidia, Fijałkowska-Lichwa
Tadeusz A., Przylibski
Maciej, Norenberg
author_facet Lidia, Fijałkowska-Lichwa
Tadeusz A., Przylibski
Maciej, Norenberg
author_sort Lidia, Fijałkowska-Lichwa
title Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland)
title_short Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland)
title_full Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland)
title_fullStr Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland)
title_full_unstemmed Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland)
title_sort intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in dobromierz (sw poland)
publisher Springer
publishDate 2023
url https://link.springer.com/article/10.1007/s10967-023-08882-9
https://dlib.phenikaa-uni.edu.vn/handle/PNK/8219
_version_ 1763815060366426112
score 8.887836