Parallel magnetic resonance imaging acceleration with a hybrid sensing approach

Q2

Lưu vào:
Hiển thị chi tiết
Tác giả chính: Anh Quang Tran
Đồng tác giả: Tien-Anh Nguyen
Định dạng: Bài Báo
Ngôn ngữ:English
Nhà xuất bản: Mathematical Biosciences and Engineering 2021
Chủ đề:
Truy cập trực tuyến:http://www.aimspress.com/article/doi/10.3934/mbe.2021116
https://dlib.phenikaa-uni.edu.vn/handle/PNK/1946
Từ khóa: Thêm từ khóa
Không có từ khóa, Hãy là người đầu tiên đánh dấu biểu ghi này!
id oai:localhost:PNK-1946
record_format dspace
spelling oai:localhost:PNK-19462022-08-17T05:54:40Z Parallel magnetic resonance imaging acceleration with a hybrid sensing approach Anh Quang Tran Tien-Anh Nguyen Phuc Thinh Doan Duc-Nghia Tran Duc-Tan Tran magnetic resonance imaging (MRI) compressed sensing (CS) random under-sampling parallel magnetic resonance imaging (pMRI) Q2 In magnetic resonance imaging (MRI), the scan time for acquiring an image is relatively long, resulting in patient uncomfortable and error artifacts. Fortunately, the compressed sensing (CS) and parallel magnetic resonance imaging (pMRI) can reduce the scan time of the MRI without significantly compromising the quality of the images. It has been found that the combination of pMRI and CS can better improve the image reconstruction, which will accelerate the speed of MRI acquisition because the number of measurements is much smaller than that by pMRI. In this paper, we propose combining a combined CS method and pMRI for better accelerating the MRI acquisition. In the combined CS method, the under-sampled data of the K-space is performed by taking both regular sampling and traditional random under-sampling approaches. MRI image reconstruction is then performed by using nonlinear conjugate gradient optimization. The performance of the proposed method is simulated and evaluated using the reconstruction error measure, the universal image quality Q-index, and the peak signal-to-noise ratio (PSNR). The numerical simulations confirmed that, the average error, the Q index, and the PSNR ratio of the appointed scheme are remarkably improved up to 59, 63, and 39% respectively as compared to the traditional scheme. For the first time, instead of using highly computational approaches, a simple and efficient combination of CS and pMRI is proposed for the better MRI reconstruction. These findings are very meaningful for reducing the imaging time of MRI systems. 2021-07-05T09:19:33Z 2021-07-05T09:19:33Z 2021 Article http://www.aimspress.com/article/doi/10.3934/mbe.2021116 https://dlib.phenikaa-uni.edu.vn/handle/PNK/1946 10.3934/mbe.2021116 en application/pdf Mathematical Biosciences and Engineering
institution Digital Phenikaa
collection Digital Phenikaa
language English
topic magnetic resonance imaging (MRI)
compressed sensing (CS)
random under-sampling
parallel magnetic resonance imaging (pMRI)
spellingShingle magnetic resonance imaging (MRI)
compressed sensing (CS)
random under-sampling
parallel magnetic resonance imaging (pMRI)
Anh Quang Tran
Parallel magnetic resonance imaging acceleration with a hybrid sensing approach
description Q2
author2 Tien-Anh Nguyen
author_facet Tien-Anh Nguyen
Anh Quang Tran
format Article
author Anh Quang Tran
author_sort Anh Quang Tran
title Parallel magnetic resonance imaging acceleration with a hybrid sensing approach
title_short Parallel magnetic resonance imaging acceleration with a hybrid sensing approach
title_full Parallel magnetic resonance imaging acceleration with a hybrid sensing approach
title_fullStr Parallel magnetic resonance imaging acceleration with a hybrid sensing approach
title_full_unstemmed Parallel magnetic resonance imaging acceleration with a hybrid sensing approach
title_sort parallel magnetic resonance imaging acceleration with a hybrid sensing approach
publisher Mathematical Biosciences and Engineering
publishDate 2021
url http://www.aimspress.com/article/doi/10.3934/mbe.2021116
https://dlib.phenikaa-uni.edu.vn/handle/PNK/1946
_version_ 1751856298012442624
score 8.891145